SpaceLogger®.A10

analogue data logging

Technical Specification:

Physical Enclosure dimensions Width: 67 mm
Depth: 67 mm
Height: 28 mm (excluding optional rubber feet)
Weight 75g
Enclosure material GP ABS (UL94-HB) plastic and acrylic
Connections Type Screwless terminals capable of accepting wire 0.32 to 0.65mm diameter (AWG 28 to 22)
Analogue Input Number of Channels 2
Range 4 to 20 mA (0 to 23 mA maximum)
Sampling Readings are sampled at 75 Hz and averaged over 1 sec
Maximum logging rate 1 Hz
Input impedance 177 ohms
Accuracy ±1% or 0.1 mA at 20 ºC over range 4 to 20 mA
Drift with temperature 100 ppm / ºC over range -40 ºC to +40 ºC
Analogue to digital converter 10-bit resolution
Switch Input Digital channel Input for logging control switch
Max input voltage Must not exceed 3V
Current out 7µA max
RS232 Input Number of channels 1
Transmission standard RS232 compatible, 8 bits and no parity
Transmission speed 9600 Baud (default) or selectable from 115200, 57600, 38400, 19200, 4800, 2400, 1200, 300 or 110 Baud
Data sample Records only the data between specified start (STX) and end (ETX) characters
RS232 Output Transmission standard RS232 compatible, 8 bits and no parity
Transmission speed 9600 Baud (default) or selectable from 115200, 57600, 38400, 19200, 4800, 2400, 1200, 300 or 110 Baud
Output rate Normal Mode: 1 data record per 1 to 60 seconds - selectable
Single sample Mode: single data record output in response to event defined by command TRIGGER
Slave Mode: rate determined by input of RS232 data sample defined by STX and ETX
Alarm Output Min output voltage VOH=1.7V Typ @ 1mA output current
Data Storage Data storage card Removable SD, MMC or MMC mobile card
Data capacity 2 GByte (max)
File system FAT16 or FAT32 with 8.3 file names
Sector size 512 Bytes
Data logging interval Normal Mode: 1 data record per 1 to 60 seconds - selectable
Single sample Mode: single data record logged in response to event defined by command TRIGGER with time delay defined by command DELAY
Slave Mode: rate determined by input of RS232 data sample defined by STX and ETX
Audible / Visual
Indicators
LED indicators Green: Ready to record data
Red: Power on, Writing data to SD card
Audio bleeper Two tone signal on correct card insertion
Single tone when data purge button depressed
Four bleeps per minute when time and date not set
Real Time Clock Accuracy ±40 ppm at 25°C
Backup battery CR2032
Power Power requirement 7 to 30 V DC
Current at 12 VDC 10 mA typical
Supply input protection Polarity reversal protected and internal resettable 140 mA fuse
Connection options (both included) 1.3 mm centre pin DC connector, or Screwless terminals (0.32 to 0.64 mm diameter, AWG 28 to 22 conductors)
Environmental Temperature range Operating: -25°C to +70°C [or dependent on card conditions]
Storage: -40°C to +70°C
Enclosure protection IP203
EMC EMC Directive 89/336/EEC - CE marked
(Emissions: EN61326:1997 inc A1/A2/A3:2003, EN60945:1997
Immunity: EN61326:1997)
FCC/CFR 47: Part 15:2004
The manufacturer reserves the right to amend the specification and therefore the information in this document may be subject to change.

SpaceLogger® is a registered trademark of Richard Paul Russell Ltd