Compare the features of the SpaceLogger models:
| .A10 | .D10 | .T10 (TextLogger) | .W10 (WindLogger) | |
| Data input format | Analogue 4-20mA - 2 channels | RS232 ASCII or binary data, 8 bits and no
parity (default). Or select from: 8 bits and even or odd parity or 7 bits and even or odd parity. |
RS232 ASCII or binary data, 8 bits and no
parity (default). Or select from: 8 bits and even or odd parity or 7 bits and even or odd parity. |
RS232 ASCII data, 8 bits no parity |
| Baud rate | N/A | Select from: 115200, 57600, 38400, 19200,
9600, 4800, 2400, 1200, 300, 110. Default = 9600 |
Select from: 115200, 57600, 38400, 19200,
9600, 4800, 2400, 1200, 300, 110. Default = 9600 |
Select from: 115200, 57600, 38400, 19200, 9600, 4800, 2400,
1200, 300, 110. Default = 9600 |
| Logging interval | Select logging interval from one sample per second, 2 sec, 5 sec or 10 sec | Logs continuously | Logs continuously | Logs continuously or select logging interval from one sample per 2 sec, 5 sec or 10 sec |
| Data sample | Data sampled at 75Hz and averaged every second | Records all data received | Records all data received | Records only the data between specified start (STX) and end (ETX) characters |
| Time stamping | - Yes, each data sample will be time stamped. - Back up battery for real-time clock |
None - date and time are identified from the cycle data downloaded from the connected machine | None | - Yes, each data sample will be time stamped. - Time-stamping may be disabled if preferred. - Back up battery for real-time clock |
| File format | - Data is stored in daily files. - Default format is .CSV; other extensions may be specified. - Each file name includes the date. |
All data is appended to one LOGFILE.SLS file (for non encrypted data) or to one LOGFILEX.SLS file (for encrypted data) | All data is appended to one LOGFILE1.TXT file | - Data is stored in daily files. - Default format is .CSV; other extensions may be specified. - Each file name includes the date. |
| Data Encryption | No | Yes - optional data encryption and checksum security | No | No |
| Data output | Yes, may be set up to output data in format stored on card. Only possible when logger powered on, memory card inserted & card not full. |
Feature may be enabled for OEM supply | Yes, may be set up to output data either: - exactly as received from data source, or - in format stored on card. Only possible when logger powered on, memory card inserted & card not full. |
Yes, may be set up to output data either: - exactly as received from data source, or - in format stored on card. Only possible when logger powered on, memory card inserted & card not full. |
| Data output format | RS232 ASCII data, 8 bits no parity | RS232 data, 8 bits no parity (if enabled) | RS232 data, 8 bits no parity | RS232 ASCII data, 8 bits no parity |
| Typical applications | - Industrial monitoring - Analogue sensor data logging |
Cleaning cycle data logging from decontamination devices for dental and medical record keeping | - RS232 printer replacement - Load cell logging - Equipment operating cycle data recording |
- Wind data recording - Weather station data logging - NMEA data logging - Other RS232 sensor monitoring |
| Customisable for OEM applications | Yes | Yes | Yes | Yes |
|
|
|
|||