Richard Paul Russell Ltd

Home > Products > SpaceLogger > SpaceLogger.W10 WindLogger > Specification

go to my cartview cart

 

SpaceLogger®.W10

WindLogger

Technical Specification:

Physical Enclosure dimensions Width: 67 mm
Depth: 67 mm
Height: 28 mm (excluding optional rubber feet)
Weight 75g
Enclosure material GP ABS (UL94-HB) plastic and acrylic
Input / Output
Capability
Sensor type Gill Instruments' WindSonic, WindObserver II and WindMaster ultrasonic wind speed and direction sensors
MetPak II weather station
Other sensors with data output starting <STX> and ending <LF>
Transmission standard RS232 compatible, 8 bits and no parity
Sensor output format Continuous mode: ASCII UV (or UVW), Polar or Tunnel from all sensors
NMEA output from MetPak II only
Transmission speed 9600 Baud (default) or selectable to 115200, 57600, 38400, 19200, 4800, 2400 or 1200 Baud
Wire acceptance 0.32 to 0.65 mm diameter (AWG 28 to 22)
Data Storage Data storage card Removable SD, MMC or MMC mobile card
Data capacity 2 GByte (max)
File system FAT16 or FAT32 with 8.3 file names
Sector size 512 Bytes
Data sample Records only the data between specified start (STX) and end (ETX) characters
Data logging interval Default is to log every data sample output - e.g. as per WindSonic setting (1, 2 or 4 readings per sec)
or select logging interval from 1 to 60 seconds
Audible / Visual
Indicators
LED indicators Green: Ready to record data
Red: Writing data to SD card
Audio bleeper Two tone signal on correct card insertion
Single tone when data purge button depressed
Four bleeps per minute when time and date not set
Real Time Clock Accuracy ±40 ppm at 25°C
Backup battery CR2032
Power Power requirement 7 to 30 V DC
Current at 12 VDC 10 mA typical
Supply input protection Polarity reversal protected and internal resettable fuse – 140 mA
Connection options (both included) 1.3 mm centre pin DC connector, or Screwless terminals (0.32 to 0.64 mm diameter, AWG 28 to 22 conductors)
Environmental Temperature range Operating: -25°C to +70°C [or dependent on card conditions]
Storage: -40°C to +70°C
Enclosure protection IP203
EMC EMC Directive 89/336/EEC - CE marked
(Emissions: EN61326:1997 inc A1/A2/A3:2003, EN60945:1997
Immunity: EN61326:1997)
FCC/CFR 47: Part 15:2004
The manufacturer reserves the right to amend the specification and therefore the information in this document may be subject to change.

SpaceLogger® is a registered trademark of Richard Paul Russell Ltd