Richard Paul Russell Ltd

Home > Products > SpaceLogger-RS > WindLogger > Specification

go to my cartview cart

SpaceLogger-RSTM WindLogger

Technical Specification:

Physical Enclosure dimensions Width: 67 mm
Depth: 67 mm
Height: 28 mm (excluding optional rubber feet)
Weight 75g
Enclosure material GP ABS (UL94-HB) plastic and acrylic
Power Supply Supply voltage 7 - 30 V dc
Supply current 10 mA typical (at 12V dc)
Supply input protection Polarity reversal protected and internal fuse – 500 mA slo-blo® (Littelfuse type 0454500 or equivalent)
Connection options (both included) 1.3 mm centre pin DC connector, or Screwless terminals (0.32 to 0.64 mm diameter conductors)
Interface Sensor type Gill Instruments' WindSonic and other compatible sensors
RS232 serial input 8 bits and no parity
Baud Rate: 9600 Baud (default) or selectable to 115200, 57600, 38400, 19200, 4800, 2400 or 1200 Baud
Wire acceptance 0.32 to 0.65 mm diameter (AWG 28 to 22)
Data Storage Data storage card Removable MMC mobile
Data capacity 2 GByte (max)
File system FAT16 or FAT32 with 8.3 file names
Sector size 512 Bytes
Data logging interval Default as per WindSonic setting (1, 2 or 4 readings per sec) or selectable to 1 reading per 2, 5 or 10 seconds
Audio/Visual Indicators LED indicators Ready to record data (green LED)
Writing data to MMC mobile card (red LED)
Audio bleeper Two tone signal on correct card insertion
Single tone when data purge button depressed
Four bleeps per minute when time and date not set
Real Time Clock Accuracy ±40 ppm at 25°C
Backup battery CR2032
Environmental Temperature range Operating: -25°C to +70°C [or dependent on card conditions]
Storage: -40°C to +70°C
Enclosure protection IP203
EMC EMC Directive 89/336/EEC - CE marked
(Emissions: EN61326:1997 inc A1/A2/A3:2003, EN60945:1997
Immunity: EN61326:1997)
FCC/CFR 47: Part 15:2004
The manufacturer reserves the right to amend the specification and therefore the information in this document may be subject to change.

SpaceLogger is a trademark of Richard Paul Russell Ltd